Communication settings
Configuration | Object | Value range | Factory settings |
---|---|---|---|
Slave address | 2028h | 1 to 247 | 5 |
Baud rate | 202Ah | 7200 to 256000 | 19200 |
Parity | 202Dh |
|
0x04 (Even) |
The number of data bits is always "8" here. The number of stop bits is dependent on
the parity setting:
- No parity: 2 stop bits
- "Even" or "Odd" parity: 1 stop bit
The following baud rates are supported:
- 7200
- 9600
- 14400
- 19200
- 38400
- 56000
- 57600
- 115200
- 128000
- 256000
You must save the changes by writing value "65766173h" in object 1010h:0Bh. The changes are not taken over until after the controller has been restarted.