Cyclic Synchronous Velocity
Overview
Description
In this mode, the controller passes a speed preset via the fieldbus at fixed time intervals (referred to in the following as a cycle). The controller then no longer calculates any ramps, but rather only follows the presets.
Activation
To activate the mode, the value "9" must be set in object 6060h (Modes Of Operation) (see "CiA 402 Power State Machine").
Controlword
In this mode, the bits of controlword 6040h have no special function.
Statusword
The following bits in object 6041h (statusword) have a special function:
Bit | Value | Description |
---|---|---|
8 | 0 | The controller is not in sync with the fieldbus |
8 | 1 | The controller is in sync with the fieldbus |
10 | 0 | Reserved |
10 | 1 | Reserved |
12 | 0 | Controller does not follow the target; the preset of 60FFh (Target Velocity) is ignored |
12 | 1 | Controller follows the target; object 60FFh (Target Velocity) is used as the input for position control. |
13 | 0 | Reserved |
13 | 1 | Reserved |
Object entries
The following objects are necessary for controlling this mode:
- 60FFh (Target Velocity): This object must be written cyclically with the speed set value.
- 6085h (Quick-Stop Deceleration): This object contains the braking deceleration for the case that a quick-stop is triggered (see "CiA 402 Power State Machine").
- 605Ah (Quick-Stop Option Code): This object contains the option that is to be executed in the event of a quick-stop (see "CiA 402 Power State Machine").
- 6080h (Max Motor Speed): Maximum speed
- 60C2h:01h (Interpolation Time Period): This object specifies the time of a cycle; a new set value must be written in 60FFh in these time intervals.
The following applies here: cycle time = value of 60C2h:01h * 10value of 60C2:02 seconds.
- 60C2h:02h (Interpolation Time Index): This object specifies the time basis of the cycles. Currently, only value 60C2h:02h=-3 is supported; this yields a time basis of 1 millisecond.
- 60B1h (Velocity Offset): Offset for the speed set value in user-defined units
- 60B2h (Torque Offset): Offset for the torque set value in tenths of a percent
The following objects can be read in this mode: