PD2-CB USB Online Manual

Pin assignment

Overview

Connection Function
X1 Voltage supply, inputs and outputs
X2 Micro USB
S1 DIP switch
L1 Power LED

Note: All pins with designation GND are internally connected.

X1 – voltage supply, inputs and outputs

Voltage source

The operating or supply voltage supplies a battery, a transformer with rectification and filtering, or a switching power supply.

Note:
  • EMC: For a DC power supply line longer than 30 m or when using the motor on a DC bus, additional interference-suppression and protection measures are necessary.
  • ► An EMI filter is to be inserted in the DC supply line as close as possible to the controller/motor.
  • ► Long data or supply lines are to be routed through ferrites.

Connections

  • Type: Phoenix Contact MCDN 1.5/ 8-G1-3.5 P26THR
  • Mating connector (included in scope of delivery): 2x Phönix Contact FMC 1.5/ 8-ST-3.5 (or equivalent)
  • Nanotec article number: ZCPHOF-MC1,5-8
Pin Function Note
a1 GND
a2 +Ub
  • PD2-C4118L1804-E-01: 12-48 V DC
  • PD2-CB42C048040-E-01: 12-48 V DC
  • PD2-CB42M024040-E-01: 12-24 V DC
a3 Digital input 1 24 V signal, max. 1 MHz
a4 Digital input 2 24 V signal, max. 1 MHz
a5 Digital input 3 24 V signal, max. 1 MHz
a6 Analog input 10 bit, 0-10 V or 0-20 mA, switchable by means of software with 3221h
a7 Digital output 1 Open drain, max. 24 V/100 mA
a8 Digital output 2 Open drain, max. 24 V/100 mA
b1 GND
b2 +10 V DC Constant output voltage, max. 150 mA
b3 -Release (-input 4) The default setting for this input combination is "single-ended"; this means that the "-Release" input is deactivated, only "+Release" against GND is active. 5 V / 24 V signal, switchable by means of software with object 3240h, max. 1 MHz
b4 +Release (+input 4)
b5 –Direction (–input 5) The default setting for this input combination is "single-ended"; this means that the "-Direction" input is deactivated, only "+Direction" against GND is active. 5 V / 24 V signal, switchable by means of software with object 3240h, max. 1 MHz
b6 Direction (+input 5)
b7 –Clock (–input 6) The default setting for this input combination is "single-ended"; this means that the "-Clock" input is deactivated, only "+Clock" against GND is active. 5 V / 24 V signal, switchable by means of software with object 3240h, max. 1 MHz
b8 Clock (+input 6)
The following switching thresholds apply for inputs 1 to 3:
Max. Voltage

Switching thresholds

(worst-case calculations)

On Off
24 V > 15.29 V < 0.97 V
The following switching thresholds apply for inputs 4 to 6 (pins b3 to b8):
Max. Voltage

Switching thresholds

(worst-case calculations)

On Off
5 V > 4.94 V < 0.48 V
24 V > 20.24 V < 2.94 V

If you set 3240h:07h to the value "1", three differential inputs are available on pins b3 to b8. Where:

Switching on Switching off
Voltage at input pin+ against GND > switch-on threshold Voltage at input pin- against GND > switch-on threshold
Connection data min max
Conductor cross section, rigid, min. 0.2 mm2 1.5 mm2
Conductor cross section, flexible, min. 0.2 mm2 1.5 mm2
Conductor cross section, flexible, min. Wire-end sleeve without plastic sleeve, min. 0.25 mm2 1.5 mm2
Conductor cross section, flexible, min. Wire-end sleeve min. Plastic sleeve min. 0.25 mm2 0.75 mm2
Conductor cross section, min. AWG 24 16
Min. AWG acc. to UL/CUL 24 16

Permissible operating voltage

Depending on the motor type, the maximum operating voltage is:

  • PD2-C4118L1804: 50.5 V DC.
  • PD2-CB42C048040: 50.5 V DC.
  • PD2-CB42M024040: 29 V DC.

If the input voltage of the controller exceeds the threshold value set in 2034h, the motor is switched off and an error triggered. Above the response threshold set in 4021h:02h, the integrated ballast circuit is activated (wirewound resistor Z32041412209K6C000 from Vishay with 3 W continuous output).

The minimum operating voltage is 11.4 V DC. If the input voltage of the controller falls below 10 V, the motor is switched off and an error triggered.

A charging capacitor of at least 4700 µF / 50 V (approx. 1000 µF per ampere rated current) must be connected in parallel to the supply voltage to avoid exceeding the permissible operating voltage (e. g., during braking).

Note:
  • Damage to the controller and/or its power supply due to excitation voltage of the motor!
  • Voltage peaks during operation may damage the controller and possibly its power supply.
  • ► Install suitable circuits (e.g., charging capacitor) that reduce voltage peaks.
  • ► With BLDC motors: Select a voltage source that corresponds to the rated voltage of the respective motor as specified in the motor data sheet.
  • ► Use a power supply with protection circuit to protect against overvoltage.

X2 − Micro USB

A cable of type "micro USB" is needed for this USB connection.

▶   next

Contents