Operating LED

Normal operation

In normal operation the green operating LED L1 flashes briefly once per second.

Error

Should there be an error, an error number is indicated by the LED, which will switch to a red color. In the following illustration, the error is signaled with the number 3.

The meaning of the error number is printed in the following table.


Amount Flash Error
1 General information
2 Voltage
3 Temperature
4 Overcurrent
5 Control

Note
A considerably more exact error code is stored in object 1003h for every error that has occurred.