2037h Open Loop Current Reduction Value/factor
Function
This object describes the rms current to which the motor current in open loop is to be reduced if the motor is at a standstill.
Object description
Index | 2037h |
Object name | Open Loop Current Reduction Value/factor |
Object Code | VARIABLE |
Data type | INTEGER32 |
Savable | yes, category: application |
Access | read / write |
PDO mapping | no |
Allowed values | |
Preset value | FFFFFFCEh |
Firmware version | FIR-v1426 |
Change history |
Description
- Value of 2037h greater than or equal to 0 and less than value 6075h
- Current is reduced to the value entered here. The value is in mA and interpreted as root mean square.
- Value of 2037h in the range from -1 to -100
-
The entered value is interpreted as a percentage and determines the reduction of the rated current in 2037h. The value in 6075h is used for the calculation.
Example: Object 6075h has the value 4200 mA. The value -60 in 2037h reduces the current by 60% of 6075h. The result is a current reduction to a root mean square of 6075h * (2037h + 100) / 100 = 1680 mA.
The value -100 in 2037h would, for example, mean that a current reduction is set to a root mean square of 0 mA.