605Ah Quick Stop Option Code
Function
The object contains the action that is to be executed on a transition of the CiA 402 Power State Machine to the Quick Stop active state.
Object description
Index | 605Ah |
Object name | Quick Stop Option Code |
Object Code | VARIABLE |
Data type | INTEGER16 |
Savable | yes, category: application |
Access | read / write |
PDO mapping | no |
Allowed values | |
Preset value | 0002h |
Firmware version | FIR-v1426 |
Change history |
Description
Value in object 605Ah | Description |
---|---|
0 | Immediate stop with subsequent state change to Switch on disabled |
1 | Braking with slow down ramp (deceleration ramp depending on operating mode) and subsequent state change to Switch on disabled |
2 | Braking with quick stop ramp (6085h) and subsequent state change to Switch on disabled |
5 | Braking with slow down ramp (deceleration ramp depending on operating mode) and subsequent state change to Quick stop active; control does not switch off and the motor remains energized. You can switch back to the Operation enabled state. |
6 | Braking with quick stop ramp (6085h) and subsequent state change to Quick Stop Active; control does not switch off and the motor remains energized. You can switch back to the Operation enabled state. |