1001h Error Register
Function
Error register: The corresponding error bit is set in case of an error. If the error no longer exists, it is deleted automatically.
Note: For each error that occurs, a
more precise error code is stored in object 1003h.
Object description
Index | 1001h |
Object name | Error Register |
Object Code | VARIABLE |
Data type | UNSIGNED8 |
Savable | no |
Access | read only |
PDO mapping | TX-PDO |
Allowed values | |
Preset value | 00h |
Firmware version | FIR-v1426 |
Change history |
Description
- GEN
- General error
- CUR
- Current
- VOL
- Voltage
- TEMP
- Temperature
- COM
- Communication
- PROF
- Relates to the device profile
- RES
- Reserved, always "0"
- MAN
- Manufacturer-specific