1017h Producer Heartbeat Time
Function
This object specifies the heartbeat time of the CANopen services network management in milliseconds. No heartbeat message is sent when the object is set to the value 0.
This object is only present in device variants with a CANopen connection.
Object description
Index | 1017h |
Object Name | Producer Heartbeat Time |
Object Code | VARIABLE |
Data type | UNSIGNED16 |
Saveable | yes, category: communication |
Access | Read/write |
PDO Mapping | No |
Admissible Values | |
Specified Value | 0000h |
Firmware Version | FIR-v1426 |
Change History |
Version FIR-v1422-B36464: Name entry changed from "Producer heartbeat time" to "Producer Heartbeat Time" |