605Ah Quick Stop Option Code
Function
The object contains the action to be executed when the " DS402 Power State machine" transitions to the Quick Stop state.
Object description
Index | 605Ah |
Object Name | Quick Stop Option Code |
Object Code | VARIABLE |
Data type | INTEGER16 |
Saveable | yes, category: application |
Access | Read/write |
PDO Mapping | No |
Admissible Values | |
Specified Value | 0001h |
Firmware Version | FIR-v1426 |
Change History |
Description
Value | Description |
---|---|
-32768 to -1 | Reserved |
0 | Immediate stop with short-circuit braking |
1 | Braking with "slow down ramp" (deceleration depending on operating mode) and subsequent state change to "Switch on disabled" |
2 | Braking with "quick stop ramp" and subsequent state change to "Switch on disabled" |
3 to 32767 | Reserved |